Detects:
• Combustible Gases
• Hydrogen
• Refrigerants: All CFC’s, HCFC’s & HFC’s
Meets and exceeds J2791 (R134a), J2913 (R1234yf) and EN 14624
The 55800 leak detector employs a new metal oxide gas sensor for the detection of chlorofluorocarbon gasses and blends. This tin oxide sensor is characterized by high sensitivity and a fast response, upon detecting the presence of extremely small levels of chlorofluorocarbon gases. Integrated into the design is a powerful
microprocessor that automatically selects the best operating conditions for the sensor, to ensure optimum performance. The optimum sensor performance is maintained and monitored throughout the life of the sensor.
- SENSITIVITY:
- HIGH ≥ 0.05 oz./yr. (1.5 g/yr.)
- MEDIUM ≥ 0.25 oz./yr. (7 g/yr.)
- LOW ≥ 0.5 oz./yr. (14 g/yr.)
- Flexible 15.5” probe for difficult to reach locations
- DISPLAY:
- Progressive LCD with vertical bars corresponding to the magnitude of the detected leak
- Visual indication of the selected sensitivity range
- SENSOR LIFE: 2000 hours
- OPERATING TEMPERATURE RANGE: 0 to 140˚F
- POWER: Two (2) D Batteries
- BATTERY LIFE: 60 hours continuous use
- “Super Sensitive Function” allows the unit further sensitizing beyond the standard settings for locating small leaks with gases such as R1234yf and R407C
| Brand | Mastercool |
|---|---|
| Manufacturer Part Number | 55800 |